Knowledge Base Article #5
Article ID: 5 - Last updated September 28, 2010 - 12:10pm
What is the accuracy, or limit of resolution that the digital pen can detect?
All versions of Capturx Pen Manager, Capturx Pen Manager 3.1, Capturx Pen Manager 3.2.1, Capturx Pen Manager 3.3, Digital Pen, FAQ
Question
What is the accuracy, or limit of resolution that the digital pen can detect?
Answer
The maximum address error the digital pen can detect is 1.0mm, or the sum total of the following conditions:
1. Anoto® pattern resolution: 0.3mm (dot pitch is 0.3mm)
2. Address errors calculated by the locations of the digital pen and Anoto patterns vary depending on the angle of the digital pen against the paper. The maximum error is 0.7mm.